EMT Y2E 132M4 – specifications
Series: Y2E
The EMT Y2E 132M4 comes from the Y2E series. The rated output is 7.5 kW. The motor is four-pole, which at 50 Hz gives a synchronous speed of 1,500 rpm. The rated voltage is 400 V. The housing is frame size 132 M in foot-mounted form. The protection class is IP55 and IP56. The efficiency is 90.1 per cent at full load, 90.2 per cent at 75 per cent load and 89.4 per cent at half load. The motor weighs 74 kg. At full load it delivers 49.6 Nm. Mounting arrangements to IEC 60034-7: B3, B5, B14, B34, B35, V1, V3 and V5. The motor is built in China. The figures come from the Australian MEPS register under standard AS/NZS 1359.5:2004; measured to IEC 60034-2-1 (Edition 2.0). The Y2E series covers 29 models. Rated output within it ranges from 0.75 to 132 kW; the Y2E 132M4 sits at the bottom of that range with 7.5 kW. Its immediate neighbours are the Y2E 132S4 below it with 5.5 kW and the Y2E 160L4 above it with 15 kW. 274 EMT models across 5 series are on record.
Build year not documented · Data origin: Official register · sources
Not the right version? The data comes from vehicle registers holding many near-identical versions side by side. Photograph the data plate — we read make and type from it. Open the scanner e-mail address required
EMT Y2E – register of three-phase motors on the Chinese Y2 platform: 29 versions, 0.75 to 132 kW, 2- to 6-pole, IP55 and IP56 protection, frame sizes 90 to 315, made in China
The Y2E range at EMT covers three-phase motors on the Y2 platform common in China, where the model name combines frame size and pole count in a single digit string, for example Y2E 200L4 for the four-pole version of frame size 200L or Y2E 315L6 for the six-pole 315L version.
Read on 3 more paragraphs
The register lists here 29 versions with 0.75 to 132 kW, two- to six-pole. Full-load efficiencies range from 80 to 95.75% and at 75% load from 79.9 to 95.89%. Frame sizes run from 90 to 315 under IEC, all motors carry protection ratings IP55 and IP56; manufacturing is exclusively in China, tested partly to AS/NZS 1359.5:2004 and partly to the GEMS determinations of 2012 and 2019, with test methods A and B. Three of the 29 versions reach the High Efficiency Level 2005 classification, the rest without a separate classification.
With a power band from under a kilowatt to 132 kW, Y2E covers the standard range of Chinese normed motors for pumps, fans, compressors and conveyors, which numerous Chinese manufacturers offer in parallel under their own brand names.
When buying used, what matters is bearing condition and a checked insulation resistance of the winding, visible overheating marks on the terminal box and fan cover, the condition of shaft and key, and a legible nameplate with frame size, pole count and protection rating; anyone needing a higher efficiency class should check the individual version's High Efficiency classification. Spares are usually available independent of manufacturer thanks to the widely used Y2 frame size.
Sources: SpecCodex register, model data: EMT Y2E
Technical data
Engine
| Rated output | 7.5 kWcorrect |
|---|
Dimensions and weights
| Weight | 74 kgcorrect |
|---|
Electrical data
| Rated voltage | 400 Vcorrect |
|---|---|
| Number of poles | 4correct |
| Protection class | IP55, IP56correct |
| Frame size | 132 M (foot)correct |
| Mounting (IEC 60034-7) | B3, B5, B14, B34, B35, V1, V3, V5correct |
| Efficiency at full load | 90.1 %correct |
| Efficiency at 75 % load | 90.2 %correct |
| Efficiency at half load | 89.4 %correct |
Origin and approval
| Country of manufacture | Chinacorrect |
|---|
Other data
| Standard applied | AS/NZS 1359.5:2004correct |
|---|---|
| Test method | IEC 60034-2-1 (Edition 2.0)correct |
Frequently asked questions
What to check before buying
- Match the data plate against the order: frame size, mounting and rating have to agree.
- Check the ingress rating against the installation site — outdoors or in dust the demands differ.
- Hold the mounting form and dimensions against the existing seat before ordering.
- The pole count sets the speed — when replacing an older unit, compare this first.
- For used units, ask about winding condition and bearing play.
- Ask about parts availability for this series — the running costs hang on it.
A general list for this type of machine — no substitute for an inspection or an appraiser.
We do not sell machines. We ask the dealers who carry this model and come back with price and lead time.
Request a quote →
We ask the suppliers and come back with price and lead time.
Request spare parts →
This page carries 24 individual figures for this model. They come from 1 recorded source; every figure can be traced there. What we cannot document is not here — we leave gaps open rather than estimate them.
Are you the manufacturer or a dealer of this machine? Check the data and add missing figures — we mark your correction as manufacturer or dealer information.
Check and complete the data →Missing a figure you were looking for? Report it →
Know this machine better? Have a photo, a manual, or know that a figure is wrong? Add it to the register →
Other models in this series
Y2E 100L14
Y2E 100L24
Y2E 112M4
Y2E 132S4
Y2E 160L4
Y2E 160M6
Y2E 180L4
Y2E 200L
Y2E 200L26
Y2E 200L4
Y2E 225M2
Y2E 225M4
Sources: Energy Rating — Australian government equipment register (retrieved August 2026) · Data sources and cross-checks
Electric motor in 3D section
Turn the model, look inside and click an assembly — each one is explained.