Technical register for agricultural, construction and commercial machinery · sourced data
Start › Electric motors › Lafert › AMHEBY › AMHEBY 80Z AA4

Lafert AMHEBY 80Z AA4

Series: AMHEBY

Source: lafert.com

Not the right version? The data comes from vehicle registers holding many near-identical versions side by side. Photograph the data plate — we read make and type from it. Open the scanner e-mail address required

The Lafert AMHEBY 80Z AA4 is a three-phase induction motor from the AMHEBY series. The rated output is 0.75 kW. The motor is four-pole, which at 50 Hz gives a synchronous speed of 1,500 rpm. The housing is frame size 80 M in foot-mounted form. The protection class is IP55. The efficiency is 80.3 per cent at full load, 80.4 per cent at 75 per cent load and 79.2 per cent at half load. Mounting arrangements to IEC 60034-7: B3, B5, B14, B34 and B35. The motor is built in Italy. The data is based on the Australian MEPS registration under the GEMS Determination 2019; measured to IEC 60034-2-1 (Edition 2.0). The AMHEBY series covers 6 models. Rated output within it ranges from 0.75 to 15 kW; the AMHEBY 80Z AA4 sits at the bottom of that range with 0.75 kW. Its immediate neighbours are the AMHEBY 90L BA4 above it with 1.5 kW. 97 Lafert models across 5 series are on record.

Lafert AMHEBY – high-efficiency motors from San Donà di Piave: MEPS-registered range, frame sizes 80 to 160, 0.75 to 15 kW, 4-pole, IP54/IP55 protection, efficiency up to 91.28%

Lafert is an Italian electric motor manufacturer headquartered in San Donà di Piave near Venice. AMHE denotes the company's high-efficiency range; the types carried in the register, such as AMHEBY 112M AA4 or AMHEBY 160L ZA4, carry the frame size as a three-digit number and the pole count as the final digit before the letter suffix, matching the frame-size and pole-count values in the register.

Read on 3 more paragraphs

The register lists here 6 versions with 0.75 to 15 kW rated output, all 4-pole, at voltages of 230/400 V and 400/690 V. Full-load efficiency ranges from 80.27 to 91.28%, and at 75% load from 80.42 to 91.46%. Frame sizes run from 80 to 160, protection is mostly IP55, with one motor at IP54. Testing followed the GEMS determinations of 2012 and 2019 using test methods A and 2-1-1B.

As a high-efficiency programme, the AMHE range targets applications where motor efficiency over the operating life matters more than purchase price, such as continuously running pumps and fans, competing with the premium motors of ABB, Siemens and WEG. The range is manufactured in Italy.

When buying used, what matters is bearing condition and a checked insulation resistance of the winding, visible overheating marks on the terminal box and fan cover, and a legible nameplate with frame size, pole count and efficiency class. Anyone wanting to run the motor on a variable-speed drive should note the voltage variant (230/400 V or 400/690 V). Spares and support run through the Lafert sales network.

Sources: SpecCodex register, model data: Lafert AMHEBY, Lafert (manufacturer)

Technical data

Engine

Rated output0.75 kWcorrect

Electrical data

Rated voltage230/400 Vcorrect
Number of poles4correct
Protection classIP55correct
Frame size80 M (foot)correct
Mounting (IEC 60034-7)B3, B5, B14, B34, B35correct
Efficiency at full load80.27 %correct
Efficiency at 75 % load80.42 %correct
Efficiency at half load79.22 %correct

Origin and approval

Country of manufactureItalycorrect

Other data

Standard appliedGreenhouse and Energy Minimum Standards (Three Phase Electric Motors) Determination 2019correct
Test methodIEC 60034-2-1 (Edition 2.0)correct

Frequently asked questions

How much power does the Lafert AMHEBY 80Z AA4 have?

The Lafert AMHEBY 80Z AA4 delivers 0.8 kW.

What to check before buying

  • Match the data plate against the order: frame size, mounting and rating have to agree.
  • Check the ingress rating against the installation site — outdoors or in dust the demands differ.
  • Hold the mounting form and dimensions against the existing seat before ordering.
  • The pole count sets the speed — when replacing an older unit, compare this first.
  • For used units, ask about winding condition and bearing play.
  • Ask about parts availability for this series — the running costs hang on it.

A general list for this type of machine — no substitute for an inspection or an appraiser.

Looking for this machine?
We do not sell machines. We ask the dealers who carry this model and come back with price and lead time.
Request a quote →
Need parts for this model?
We ask the suppliers and come back with price and lead time.
Request spare parts →

This page carries 21 individual figures for this model. They come from 1 recorded source; every figure can be traced there. What we cannot document is not here — we leave gaps open rather than estimate them.

Missing a figure you were looking for? Report it →

Know this machine better? Have a photo, a manual, or know that a figure is wrong? Add it to the register →

Other models in this series

Sources: Energy Rating — Australian government equipment register (retrieved August 2026) · How we check the data

Electric motor in 3D section

Turn the model, look inside and click an assembly — each one is explained.

Compare