Technical register for agricultural, construction and commercial machinery · sourced data
Start › Electric motors › Jlem › Other models › JL1-160M2-2

Jlem JL1-160M2-2

Series: Other models

Not the right version? The data comes from vehicle registers holding many near-identical versions side by side. Photograph the data plate — we read make and type from it. Open the scanner e-mail address required

The Jlem JL1-160M2-2 is a three-phase induction motor built by Jlem. The rated output is 15 kW. The motor is two-pole, which at 50 Hz gives a synchronous speed of 3,000 rpm. The rated voltage is 415 V. The housing is frame size 160 M in foot-mounted form. The protection class is IP55. The efficiency is 92.1 per cent at full load, 91.8 per cent at 75 per cent load and 90.4 per cent at half load. The mounting arrangement to IEC 60034-7 is B3. The motor is built in China. The data is based on the Australian MEPS registration under the GEMS Determination 2012; measured to IEC 60034-2-1 (Edition 2.0). Rated output across the Jlem range ranges from 3 to 160 kW; the JL1-160M2-2 sits at the bottom of that range with 15 kW. Its immediate neighbours are the JM3 160M-2-11.00kW380 below it with 11 kW and the JM3 160L-2-18.50kW380 above it with 18.5 kW. 18 Jlem models across 2 series are on record.

JLEM – other models: the collective page of MEPS-registered three-phase motors outside the named ranges, frame sizes 132 to 315, 5.5 to 160 kW, 2- to 4-pole, manufactured in China

JLEM is a manufacturer name carried in the Australian energy-efficiency register for three-phase motors; no further confirmed company data is available. This page gathers the JLEM motors the register (GEMS/MEPS) could not assign to a named range. The model designations JL1-132S1-2, JL1-132S2-2, JL1-160M1-2 and JL1-160M2-2 follow a scheme of frame size (132, 160), a build-length code (S1, S2, M1, M2) and the pole count at the end; JM3-315L1-4, with frame size 315, marks the largest version in the register.

Read on 3 more paragraphs

The register lists here 5 versions with 5.5 to 160 kW rated output, two- to four-pole, at voltages from 400 to 415 V. Full-load efficiency ranges from 88.9 to 95.7%, and at 75% load from 88.7 to 95.8%. Protection is IP55 on four motors and IP45 on one; frame sizes run from 132 to 315. Testing mostly followed the 2012 GEMS determination and, for one version, the 2019 determination, with test method B or 2-1-1B; four of the five versions are assessed for High Efficiency classification and none reaches a High Efficiency Level. The mounting form is B3 on four motors, extended with B35 and V18 on one.

With a span from 5.5 to 160 kW, the range covers both smaller standard motors and larger versions for pumps, fans, compressors and conveying plant in industry; the mostly two-pole design of the smaller frame sizes points to high-speed applications.

When buying used, bearing condition and a checked insulation resistance of the winding, the condition of shaft and key, visible corrosion on the terminal box and fan cover, and a legible nameplate with frame size, pole count and voltage matter; on the IP45 version, use in dusty or damp environments should be checked beforehand. Spares run through the relevant JLEM distribution.

Sources: SpecCodex register, model data: JLEM (weitere Modelle, MEPS-Registrierungen)

Technical data

Engine

Rated output15 kWcorrect

Electrical data

Rated voltage415 Vcorrect
Number of poles2correct
Protection classIP55correct
Frame size160 M (foot)correct
Mounting (IEC 60034-7)B3correct
Efficiency at full load92.1 %correct
Efficiency at 75 % load91.8 %correct
Efficiency at half load90.4 %correct

Origin and approval

Country of manufactureChinacorrect

Other data

Standard appliedGreenhouse and Energy Minimum Standards (Three Phase Electric Motors) Determination 2012correct
Test methodIEC 60034-2-1 (Edition 2.0)correct

Frequently asked questions

How much power does the Jlem JL1-160M2-2 have?

The Jlem JL1-160M2-2 delivers 15 kW.

What to check before buying

  • Match the data plate against the order: frame size, mounting and rating have to agree.
  • Check the ingress rating against the installation site — outdoors or in dust the demands differ.
  • Hold the mounting form and dimensions against the existing seat before ordering.
  • The pole count sets the speed — when replacing an older unit, compare this first.
  • For used units, ask about winding condition and bearing play.
  • Ask about parts availability for this series — the running costs hang on it.

A general list for this type of machine — no substitute for an inspection or an appraiser.

Looking for this machine?
We do not sell machines. We ask the dealers who carry this model and come back with price and lead time.
Request a quote →
Need parts for this model?
We ask the suppliers and come back with price and lead time.
Request spare parts →

This page carries 22 individual figures for this model. They come from 1 recorded source; every figure can be traced there. What we cannot document is not here — we leave gaps open rather than estimate them.

Missing a figure you were looking for? Report it →

Know this machine better? Have a photo, a manual, or know that a figure is wrong? Add it to the register →

Other models in this series

Sources: Energy Rating — Australian government equipment register (retrieved August 2026) · How we check the data