Technical register for agricultural, construction and commercial machinery · sourced data

Ingersoll Rand 3000D30

Series: Other models

The photo shows the 2475B5 from the same series. Source: shop.ingersollrand.com

Not the right version? The data comes from vehicle registers holding many near-identical versions side by side. Photograph the data plate — we read make and type from it. Open the scanner e-mail address required

The Ingersoll Rand 3000D30 is a three-phase induction motor. The rated output is 11 kW. The motor is four-pole, which at 50 Hz gives a synchronous speed of 1,500 rpm. The rated voltage is 400 V. The housing is frame size 160 M in foot-mounted form. The protection class is IP54. The efficiency is 90 per cent at full load, 89 per cent at 75 per cent load and 78.9 per cent at half load. The mounting arrangement to IEC 60034-7 is B3. The motor is built in China. The data is based on the Australian MEPS registration under standard AS/NZS 1359.5:2000 (Legacy); measured to AS 1359.102.1:1997. Rated output across the Ingersoll Rand range ranges from 0.75 to 160 kW; the 3000D30 sits at the bottom of that range with 11 kW. Its immediate neighbours are the M90/M160 - Cooling Fan Motor below it with 9 kW and the "24177594" above it with 15 kW. 360 Ingersoll Rand models across 16 series are on record.

Ingersoll Rand – other models: the collective page of three-phase motors from the Australian GEMS/MEPS register, 0.75 to 160 kW, 2- to 6-pole, Chinese manufacture, efficiencies up to 96.1%

This page gathers the three-phase motors registered under the Ingersoll Rand brand in the Australian GEMS/MEPS register that could not be assigned to a named range. Ingersoll Rand is best known for compressed-air and compressor technology; the motors recorded here include typical drive motors for compressor packages and related units in this size class. All 181 models come from Chinese manufacture. Some of the type codes are plain order or part numbers (for instance 18993055), others are short frame-size codes such as 112M, 132S or 315L following the IEC scheme; no consistent type logic spanning both naming styles can be derived from them.

Read on 3 more paragraphs

The register lists here 181 versions from 0.75 to 160 kW, 2- to 6-pole, with efficiencies from 72.12 to 96.1% at full load and 70.12 to 96.36% at 75% load, mostly protection class IP55 (alongside IP54 and IP56), and frame sizes from 90 to 315 (IEC). Of the 162 models with a GEMS classification recorded, 9 reach the "2005 High Efficiency Level"; the rest carry no such classification.

In the register, Ingersoll Rand thus mainly reflects the drive-motor requirements of its own compressor production; the range of frame sizes and outputs visibly follows the requirements of different compressor ranges rather than a standalone electric-motor catalogue.

For used Ingersoll Rand drive motors, the usual checkpoints apply: measure the winding's insulation resistance, check the bearings for running noise and play, check the shaft turns freely, assess the condition of the fan and fan cowl, and match frame size, pole count and efficiency class on the rating plate against the original compressor unit, if the motor came from such an assembly. For inverter operation, check separately whether the winding insulation and bearings are rated for it.

Sources: SpecCodex register, model data: Ingersoll Rand – weitere Modelle, Ingersoll Rand, GEMS-Register (Greenhouse and Energy Minimum Standards, Australien)

Technical data

Engine

Rated output11 kWcorrect

Electrical data

Rated voltage400 Vcorrect
Number of poles4correct
Protection classIP54correct
Frame size160 M (foot)correct
Mounting (IEC 60034-7)B3correct
Efficiency at full load90 %correct
Efficiency at 75 % load89 %correct
Efficiency at half load78.88 %correct

Origin and approval

Country of manufactureChinacorrect

Other data

Standard appliedAS/NZS 1359.5:2000 (Legacy)correct
Test methodAS 1359.102.1:1997correct

Frequently asked questions

How much power does the Ingersoll Rand 3000D30 have?

The Ingersoll Rand 3000D30 delivers 11 kW.

What to check before buying

  • Match the data plate against the order: frame size, mounting and rating have to agree.
  • Check the ingress rating against the installation site — outdoors or in dust the demands differ.
  • Hold the mounting form and dimensions against the existing seat before ordering.
  • The pole count sets the speed — when replacing an older unit, compare this first.
  • For used units, ask about winding condition and bearing play.
  • Ask about parts availability for this series — the running costs hang on it.

A general list for this type of machine — no substitute for an inspection or an appraiser.

Looking for this machine?
We do not sell machines. We ask the dealers who carry this model and come back with price and lead time.
Request a quote →
Need parts for this model?
We ask the suppliers and come back with price and lead time.
Request spare parts →

This page carries 22 individual figures for this model. They come from 1 recorded source; every figure can be traced there. What we cannot document is not here — we leave gaps open rather than estimate them.

Missing a figure you were looking for? Report it →

Know this machine better? Have a photo, a manual, or know that a figure is wrong? Add it to the register →

Other models in this series

Sources: Energy Rating — Australian government equipment register (retrieved August 2026) · How we check the data

Electric motor in 3D section

Turn the model, look inside and click an assembly — each one is explained.

Compare