The ABB M3JP 200MLA 2 is a three-phase induction motor. The rated output is 22 kW. The motor is two-pole, which at 50 Hz gives a synchronous speed of 3,000 rpm. The housing is frame size 200. The protection class is IP55, IP56, IP65 and IP66. The efficiency is 90.8 per cent at full load, 91.8 per cent at 75 per cent load and 91.7 per cent at half load. Mounting arrangements to IEC 60034-7: B3, B5, B8, B35, V1, V3, V5 and V6. Stated countries of manufacture: Finland and Poland. The data is based on the Australian MEPS registration under the GEMS Determination 2012; measured to IEC 60034-2-1 (Edition 2.0). Rated output across the ABB range ranges from 0.75 to 185 kW; the M3JP 200MLA 2 sits at the bottom of that range with 22 kW. Its immediate neighbours are the M3KP225SMA8 below it with 18.5 kW and the M3AA 160MLE 2G above it with 27 kW. 2143 ABB models across 2 series are on record. The model is listed under Electric motors. 25 verified figures from 1 source are on file.

Technical data

Engine

Engine familyM3correct
Engine familiesM3correct
Rated output22 kWcorrect

Electrical data

Number of poles2correct
Protection classIP55, IP56, IP65, IP66correct
Frame size200correct
Mounting (IEC 60034-7)B3, B5, B8, B35, V1, V3, V5, V6correct
Efficiency at full load90.8 %correct
Efficiency at 75 % load91.8 %correct
Efficiency at half load91.7 %correct

Origin and approval

Country of manufactureFinland, Polandcorrect
Standard appliedGreenhouse and Energy Minimum Standards (Three Phase Electric Motors) Determination 2012correct
Test methodIEC 60034-2-1 (Edition 2.0)correct

Frequently asked questions

How much power does the ABB M3JP 200MLA 2 have?

The ABB M3JP 200MLA 2 delivers 22 kW.

What to check before buying

  • Match the data plate against the order: frame size, mounting and rating have to agree.
  • Check the ingress rating against the installation site — outdoors or in dust the demands differ.
  • Hold the mounting form and dimensions against the existing seat before ordering.
  • The pole count sets the speed — when replacing an older unit, compare this first.
  • For used units, ask about winding condition and bearing play.
  • Ask about parts availability for this series — the running costs hang on it.

A general list for this type of machine — no substitute for an inspection or an appraiser.

Looking for this machine?
We do not sell machines. We ask the dealers who carry this model and come back with price and lead time.
Request a quote →
Need parts for this model?
We ask the suppliers and come back with price and lead time.
Request spare parts →

This page carries 25 individual figures for this model. They come from 1 recorded source; every figure can be traced there. What we cannot document is not here — we leave gaps open rather than estimate them.

Missing a figure you were looking for? Report it →

Know this machine better? Have a photo, a manual, or know that a figure is wrong? Add it to the register →

Other models in this series

Sources: [1]

Electric motor in 3D section

Turn the model, look inside and click an assembly — each one is explained.

Compare